Acoustic insulation

Acoustic insulation of autoclaved aerated concrete walls — sound reduction indices for interior and exterior partitions.

Acoustic insulation of aerated concrete walls

Acoustic resistance of materials is associated with the right of weight. The heavier the construction material, the better it insulates and dampens sound. In the case of walls made of AAC, it turns out that the porous structure of AAC gives this material a bonus of 2-3 decibels with respect to acoustic resistance, enhancing the acoustic resistance of building partitions compared to the materials of the same weight.

Walls of AAC were tested at the Acoustics Department of the Building Research Institute. On the basis of laboratory tests and obtained indicators of acoustic resistance adjusted by 2 dB, design values ​​of acoustic resistance indicators RA1R and RA2R have been specified.

THE INDICATOR OF ACOUSTIC RESISTANCE ASSESSMENT RA1R AND RA2R [dB] FOR WALLS MADE OF BLOCKS DEPENDING ON THE WALL DENSITY AND THICKNESS CLASS IN ACCORDANCE WITH EN 20140-3

Density class The value of single number ratios RA1R and RA2R [dB] for wall thickness without plaster [mm]
RA1R – for interior wall RA2R – for exterior wall
75 100 115 150 175 200 240 300 365 420 75 100 115 150 175 200 240 300 365 420
350 – – 37 – – 43 45 – – – – – 34 – – 39 41 –
400 – – – – 38 – 41 44 46 47 – – – – 35 – 38 40 42 44
500 31 35 – 39 – 42 – – – – 30 33 – 36 – 39 – – – –
600 – – 37 – 43 – 46 48 50 – – – 35 – 39 – 42 45 47 –